    2

Requirements for the Maximum Travel Distance to an Exit as provided in PD1185 FIre Code of the Philippines ([Rule III Sec. 3.4-3.16). .

Without automatic fire suppression system - 46 meters
With automatic fire suppression system - 61 meters

Exemptions:
Educational Occupancy
Child Day Care Centers
(a) ≤ 30.5 m (any room or intended as exit access)
(b) ≤ 45.8 m (any point in a room)
(c) ≤ 15.25 m (any point in a sleeping room)
(d) travel distance in (a) and (b) may be increased by 15.25 m when equipped with automatic fire suppression system

Institutional Occupancy
Hospital, Nursing Homes and Residential Custodial Care
(a) ≤ 30 m (any room or intended as exit access
(b) ≤ 46 m (any point in a room)
(c) ≤ 15 m (any point in a sleeping room)
(d) travel distance in (a) and (b) may be increased by 15 m when equipped with automatic fire suppression system

Residential Occupancy
Hotels – Maximum 30 m
Apartment Buildings – Maximum of 31 m from entrance door or 46.5 m when protected by automatic suppression system
Dormitories – Maximum of 30.48 m or 46 m when protected by automatic suppression system

Special Purpose Industrial Occupancy and Storage Occupancy
Maximum of 23 m

Business Occupancy
Maximum of 91.5 m when protected by automatic suppression system

Mercantile Occupancy
Maximum of 30.5 m or 46 m when protected by automatic suppression system

2 comments:
Write comments
  1. thank you po s post :) d ko kc mkta ung dstnce s fire code.

    ReplyDelete
  2. Hello. Is there a provision from the code regarding the distance between two fire exits? Thank you!

    ReplyDelete

Random Posts

  • Review Questions: History Quiz 03
    24.02.2009 - 2 Comments
    Here's History and Theory of Architecture 06 Quiz. There will be 15 questions randomly picked from a…
  • Design Review for Architecture Board Exam
    07.08.2012 - 1 Comments
    The UAP Center for Career Development will soon start review class for the January 2013 Board Exam for…
  • Creating Architectural Animations with Photoshop CS4 Extended
    29.01.2009 - 0 Comments
    Photoshop can be used for much more than pixel pushing these days. Photoshop CS4 Extended not only handles 3D…
  • Photovoltaics: Design and Installation Manual
    08.03.2009 - 0 Comments
    Producing electricity from the sun using photovoltaic (PV) systems has become a major industry worldwide. But…
  • A unique village in Azerbaijan
    17.03.2009 - 0 Comments
    Here's a unique village in the Iranian province of East Azerbaijan, on northern slope of extinct volcano. The…

ArkiReview

ATLAS_CPED ArkiReview

More Services

  • Send an Email

Blog Archive

© 2014 Architecture Overload. Designed by Bloggertheme9 | Distributed By Gooyaabi Templates
Powered by Blogger.